  • OLIVER DVR 动态电压恢复器.jpg
OLIVER DVR 动态电压恢复器.jpg
+

Dynamic Voltage Restorer

RUHSTRAT OLIVER DVR Dynamic Voltage Restorer, mainly composed of an energy storage element, inverter, transfer switch, bypass, etc., connected in series between the power supply and the protected load. Once a deviation from the rated voltage level is detected, the DVR immediately cuts off the input power supply and temporarily provides the load with quality qualified electrical energy.

  • Commodity name: Dynamic Voltage Restorer
  • Commodity ID: Dynamic Voltage Restorer
  • Product Description
  • Summary
  • Working Principle

    Grid voltage within limit:

    When the grid supplies power to the load (online mode), the inverter sleeps but maintains synchronization with the grid voltage to act immediately during grid disturbances.

     

    When voltage sag occurs:

    At the moment of grid disturbance, the anti-parallel thyristor quickly turns off, isolating the load from the grid, and the inverter supplies power to the load.

     

    Grid voltage stabilizes again:

    OLIVER anti-parallel thyristor conducts, the inverter circuit shuts down, the load is powered by the grid again, and the rectifier circuit recharges the energy storage capacitor.

     

    Fault safe bypass operation:

    In case of OLIVER fault or maintenance, the load current will automatically transfer to the fault safe bypass. That is, the current will pass through the contactor or bypass switch of the anti-parallel thyristor to directly supply the load.

     

    Technical Parameters

    Serial Number

    Project Category

    Parameter

    Input Characteristics

    Grid Voltage Range

    AC400V±15%

    Rated Power

    50/60Hz±10%

    Overvoltage Level

    III

    Output Characteristics

    Minimum Residual Voltage (Umin)

    0%

    Output Wiring Method

    Three-phase Four-wire System

    Compensation Time

    Standard model compensates 0~100% residual voltage to 100%, lasting 3s; other specifications customizable;

    Common Capacity

    50/75/100/200/300/400/500/800/1200/1500kVA

    Switching Voltage Threshold

    Continuously adjustable, gradient 0.1V

    Voltage Setting Time

    1~5ms

    Response Time

    <1ms

    Cooling Method

    Air Cooling

    Output Frequency

    50/60Hz±1%

    Overload Capacity

    150%——60s

    Voltage Distortion (THDu)

    Under linear load conditions, THDu < 2.5%

     

     

    Voltage Unbalance (Negative Sequence/Positive Sequence)

    Under 100% unbalanced load < 3%

    Protection Current

    200%

    Noise

    < 65dB

    Protection Functions

    Power-on self-test, power semiconductor device fault protection, DC bus overvoltage, DC bus undervoltage, fan protection, voltage and current transformer disconnection protection, overload protection.

    Energy Storage Section

    Energy Storage Component

    Super Capacitor

    Overload Capacity

    200%

    Display

    10-inch Touch Screen

    Communication

    Modbus/TCP, Ethernet/485

  • RUHSTRAT OLIVER DVR Dynamic Voltage Restorer, mainly composed of an energy storage element, inverter, transfer switch, bypass, etc., connected in series between the power supply and the protected load. Once a deviation from the rated voltage level is detected, the DVR immediately cuts off the input power supply and temporarily provides the load with quality qualified electrical energy.